Yulong India’s 2nd International Biomass Energy and Technology Exhibition
10/14/2025
Explore the core technology of Yulong welding workshop!
10/17/20251.Detect fan speed
Unstable fan speed is a key factor leading to abnormal fan vibration, increased noise, decreased efficiency, and shortened equipment life. To check the speed, use a speed meter. Scan the fan shaft for inspection. Check and record the actual speed according to process standards to see if it is close to the rated speed.
2.Detect voltage and current
Measure the line voltage between the three phases at the motor terminals using a multi-function clamp-on ammeter. Clamp each phase power line separately using a clamp-on ammeter. Measure the operating current of each phase to verify compliance with specified standards.Clamp each phase power line separately using a clamp-on ammeter. Measure the operating current of each phase to verify compliance with specified standards.
3.Detect bridge vibration
The fan bridge is a key structure connecting the fan body to the base. Its vibration value directly reflects the overall dynamic balance and structural stability of the fan. During testing, attach the vibration sensor of the vibration detector vertically to the fan bridge near the bearing seat. Measure and record the values multiple times to check whether they meet the specified standards.
4.Detection of volute vibration
Checking volute vibration can help determine the impeller’s condition. During testing, attach the vibration sensor of the vibration detector vertically to the side of the fan volute. Once the value stabilizes, record it and check whether it meets the specified standards.