< img height="1" width="1" style="display:none" src="https://www.facebook.com/tr?id=4184978094946615&ev=PageView&noscript=1" /> In the current situation Is the permanent magnet motor the best choice for pellet machines?

In the current situation Is the permanent magnet motor the best choice for pellet machines?

High efficiency hammer mill(2)Grinding equipment

08/01/2025

why is a three-phase asynchronous motor chosen instead of a permanent magnet motor?

08/07/2025

High efficiency hammer mill(2)Grinding equipment

08/01/2025

why is a three-phase asynchronous motor chosen instead of a permanent magnet motor?

08/07/2025

First of all, the energy efficiency performance of permanent magnet motors

  1. Comparison between permanent magnet motor and three-phase asynchronous motorIn the general publicity, the energy efficiency advantage of permanent magnet motors is often highlighted by comparing with three-phase asynchronous motors with low energy efficiency levels. However, under the current technical level, when compared with the three asynchronous motors with the first-level energy efficiency of the new national standard, the energy efficiency advantage of permanent magnet motors is not obvious, and it has only increased by 2%. It is worth noting that permanent magnet motors can indeed show energy efficiency advantages under variable load and low load conditions. This is why electric vehicles widely use permanent magnet motors.
  2. Energy efficiency performance under full load conditionsThe main motor of the pellet machine is usually in full load operation. At the current technical level, in this application scenario, the energy efficiency of the permanent magnet motor is comparable to that of the three-phase asynchronous motor. Therefore, the energy efficiency advantage of the permanent magnet motor under full load conditions is not significant.
  3. Power and output of permanent magnet motorIn the pelleting industry, manufacturers often pursue high output at the same cost to increase corporate profits. Most manufacturers generally believe that permanent magnet motors have higher output than three-phase asynchronous motors at the same power. They believe that permanent magnet motors are the ideal choice due to their external advantages such as smaller design. However, this is not the case. For example, when the rated power is 280 kilowatts and the dimensions seem to be the same, the actual operation of permanent magnet motors can reach 400 kilowatts. Therefore, it is not surprising that the output has increased. This also explains the reason for its high output to a certain extent. However, the actual cost is calculated based on the actual energy consumption, so there is no reduction in cost. Moreover, the output torque of the 400-kilowatt permanent magnet motor has exceeded the design tolerance of the pelletizer reducer, which will greatly reduce the service life of the reducer and pose a huge safety hazard.